Vibrocompaction uses a depth vibrator to rearrange particles in suitable loose granular soil into a denser state. Fines content and soil variability influence how effectively densification occurs. The method and ground response differ from vibro replacement with aggregate columns.
Verify improvement in the target layer
Review baseline soundings, define target depths and choose a trial spacing pattern. Compare post-treatment measurements at representative locations and times, allowing for groundwater and testing effects where relevant. To address liquefaction, check whether the improved resistance meets the adopted triggering analysis throughout the susceptible layers, including weak pockets between treatment points.
Why test between vibrocompaction points?