Automated geotechnical monitoring can provide frequent readings but needs checks for missing records, drift and changes in equipment. A real construction event and a logger reset can each appear as a sudden step. Raw records and an event log help distinguish the two.
Keep flagged data visible and traceable
Check timestamps, units, range and rate of change. Flag questionable records and retain the raw measurements along with corrections or decisions to exclude a reading. Compare neighboring instruments and site events. An unreported interpolation across a gap can conceal the very movement the system needs to detect. Make gaps and quality flags visible to the decision team.
What should happen after a sensor is replaced?
Retain the old record, document the replacement and new reference, and check for offsets before linking the series for interpretation.
References
- USACE — Dam Safety Engineering Manuals, including EM 1110-2-1908 on instrumentation
- University of Cambridge repository — Beyond Digital Shadows: A Digital Twin for Monitoring Earthwork Operation